Skip to content

Switching to LED lighting: how to calculate energy savings

EV Sun team · 14/11/2026 · 5 min read

Power, luminous flux and operating hours: a worked energy-use example and a guide to comparing light sources before replacement.

Start a lighting upgrade by listing what is already installed in each room. Note the light source type, number of lighting points, power and operating hours. Then compare the LED replacement. Lower power means less energy use over the same operating time, but you also need to check the light output.

The LED replacements tool and energy savings calculator on the EV Sun website help you make this comparison. The first shows luminous flux and power before and after replacement. The second calculates energy use from the number of lighting points, operating hours, days per year and the price per kilowatt-hour you enter.

Lumens first, watts second

Luminous flux in lumens tells you how much light a source or luminaire provides. Power in watts is used to calculate energy consumption. Replacing a source with a much lower light output may reduce the bill without meeting the room's lighting needs. That is why the LED replacements table compares both values.

We use typical luminous flux values for existing lighting. Power before replacement includes ballast losses where a ballast is present. EV Sun specifications are checked against the data for the specific variant. For larger premises, supplement the source comparison with a luminaire layout design rather than assuming a one-for-one replacement at every lighting point.

Example: GU10 halogen and LED

A typical 50 W GU10 halogen bulb provides around 350 lm. The EVLN‑GU10 bulb is listed at 7 W and 800 lm in the product data. This comparison shows that the difference in power alone does not describe the full change. Before replacing it, also check that the light source suits the luminaire and the lighting required.

For this worked example, assume one lighting point operates for 3 hours a day, 365 days a year: a total of 1,095 hours. A 50 W halogen bulb will use 54.75 kWh in that time. A 7 W source will use 7.665 kWh. The annual difference is 47.085 kWh per lighting point.

  • One 50 W lighting point, 1,095 h per year: around 54.8 kWh.
  • One 7 W lighting point, 1,095 h per year: around 7.7 kWh.
  • Difference per lighting point: around 47.1 kWh per year.
  • At an example price of 1 PLN/kWh: around PLN 47 saved per year per lighting point.

The price of 1 PLN/kWh is an assumption for this example, not a supplier's tariff or a promise of energy costs. Enter the rate from your own bill in the calculator. When comparing offers, check which charges you are including. The actual result will also change if the operating hours change after replacement.

How the number of lighting points and calculation period affect the result

For ten such lighting points, the difference is around 471 kWh per year. At the example price of 1 PLN/kWh, that is around PLN 471. Over five years, with operating hours and the price unchanged, the difference is around 2,354 kWh and PLN 2,354 in energy costs.

This is a forecast based on the same assumptions each year. It excludes the purchase price, installation costs, tariff changes and later changes in use. Energy cost savings alone are therefore not enough to calculate the payback period. An actual quotation for the investment is also needed.

Not all tubes have a similar light output

With T8 tubes, it is particularly easy to confuse a matching length with a comparable light output. EV Sun lists the EVLN‑600T8-9W model at 990 lm. Compared with the typical 1,350 lm of an existing 18 W fluorescent tube, this is below the approximately 90% luminous flux threshold used in the table. This case calls for a lighting design.

For the 120 cm length, the EVLN‑1200T8-30W variant provides 3,300 lm, while the EVLN‑1200T8-18W provides 1,980 lm. The typical luminous flux of an existing 36 W T8 fluorescent tube used for comparison is around 3,350 lm. Choosing solely on the basis of the lowest power would therefore give a different lighting result from a comparison based on lumens.

For a 400 W metal halide lamp with a typical luminous flux of around 32,000 lm, the table specifies two EVLN‑HBN 150 W luminaires. Each provides 16,500 lm, giving a total of 33,000 lm and 300 W. The layout of the two luminaires in the existing installation still needs to be checked.

Plan the full scope of replacement

List rooms with different operating hours separately. A warehouse, office and corridor do not necessarily need lighting for the same number of hours. If the replacement covers several luminaire families, calculate them separately. This summary is easier to compare with your bill and use when preparing a lighting design.

Check the proposed family in LED replacements, then open the product datasheet for EVLN‑GU10, EVLN‑T8 LED tubes or EVLN‑HBN luminaires. The energy savings calculator shows the annual difference and the five-year result. The lighting calculator estimates the number of luminaires needed in a room. Send your floor plans and summary via Contact.

EVLN technology as an additional feature

While the luminaire is switched on, EVLN technology reduces and limits bacteria, fungi and mould in the air and on surfaces. This is a separate product feature, which we do not count as an additional financial saving. The Research section sets out the test conditions for the technology, and model documentation is available in Downloads.

Frequently asked questions

Does the calculator show the purchase payback period? It shows the difference in energy use and costs based on the assumptions entered. Calculating the payback period also requires the luminaire prices, installation costs and scope of work. Without these figures, we do not state a specific period.

Does lower power always mean a suitable replacement? No. Compare luminous flux, installation conditions and application. For tubes, also check the luminaire conversion requirements in the instructions for your chosen light source.

How do I calculate the whole building? Divide it by room and lighting hours, prepare a list of lighting points and floor plans. Use the energy savings calculator and lighting calculator, then send the summary via Contact.

Looking for a luminaire for your space? Choose a luminaire or calculate how many luminaires you need.